What is the IK rating standard for indoor lighting?

(Summary description)The IK Rating refers to the impact protection level of the equipment case. Usually, we will require both IK rating and IP rating of the equipment. 

  • Categories:News
  • Author:Pinkney
  • Origin:https://www.sohu.com/a/296380700_100224485
  • Time of issue:2022-08-22 14:09
  • Views:
Information

The IK Rating refers to the impact protection level of the equipment case. Usually, we will require both IK rating and IP rating of the equipment. For outdoor electronic equipment, whether it is overhead, buried or ordinary outdoor placement, it needs to have corresponding IP and IK Rated requirements. The IK Rating is determined by the free fall impact of the pendulum in joules. The specific reference standard is the protection level (IK code) of the electrical equipment enclosure against external mechanical impact.

Use of the IK code

Generally to say, the degree of protection applies to the overall housing. If some parts of the case have different IK Rateing, the corresponding protection levels should be marked. If the relevant product committee decides to require the marking of the IK code, the marking requirements shall be specified in detail in the relevant product standard. The product standard should also specify the marking method to be used in the following cases:

1. The protection level of one part of the same case is different from that of other parts;

2. The installation status will affect the protection level of the enclosure.

The IK level is an internationally accepted digital code used to indicate the degree of protection of electrical equipment enclosures against external mechanical impacts. According to IEC 62262:2002 and IEC 60068-2-75:1997 standards, it is the protection ability of electrical equipment enclosures for internal equipment when subjected to external impact.

IK00 - Unprotected

IK01 - Withstand 0.14J impact force (equivalent to the impact of a 0.25KG object falling from a height of 56mm on the surface)

IK02 - Withstand 0.2J impact force (equivalent to the impact of a 0.25KG object falling from a height of 80mm on the surface)

IK03 - Withstand 0.35J impact force (equivalent to the impact of a 0.2KG object falling from a height of 140mm on the surface)

IK04 - Withstand 0.5J impact force (equivalent to the impact of a 0.25KG object falling from a height of 200mm on the surface)

IK05 - Withstand 0.7J impact force (equivalent to the impact of a 0.25KG object falling from a height of 280mm on the surface)

IK06 - Withstand 1J impact force (equivalent to the impact of a 0.25KG object falling from a height of 400mm on the surface)

IK07 - Withstand 2J impact force (equivalent to the impact of a 0.5KG object falling from a height of 400mm on the surface)

IK08 - Withstand 5J impact force (equivalent to the impact of a 1.7KG object falling from a height of 300mm on the surface)

IK09 - Withstand 10J impact force (equivalent to the impact of a 5KG object falling from a height of 200mm on the surface)

IK10 - withstand 20J impact force (equivalent to the impact of a 5KG object falling from a height of 400mm on the surface)

 

Light+Building 2024 exhibition for Frankfurt, Germany

Light+Building 2024 exhibition for Frankfurt, Germany

Welcome visit Toppo Lighting coming exhibition: Frankfurt, Germany; 3-8th/Mar, 2024 Booth: 10.1 E30
 Light + Intelligent Building Middle East

Light + Intelligent Building Middle East

Welcome visit Toppo Lighting coming exhibition: Dubai, 16 - 18th/Jan, 2024 Booth: Z2-F40
Hong Kong International Lighting Fair(Autumn Edition)

Hong Kong International Lighting Fair(Autumn Edition)

Welcome to visit Toppo Booth 5E-D04 at Hong Kong International Lighting Fair (Autumn Edition), 27th-30th/Oct,2023.
Lighting Exhibition Invitation

Lighting Exhibition Invitation

Now we are going to attend the Hong Kong International Lighting Fair (Spring Edition) on April 12-15, 2023 and the Guangzhou International Lighting Exhibition on June 9-12, 2023.
Hong Kong International Lighting Fair Invitation

Hong Kong International Lighting Fair Invitation

Welcome to visit Toppo booth 1A-D40 at Hong Kong International Lighting Fair (Spring Edition), April 12-15, 2023.
2023 Spring Festival

2023 Spring Festival

According to the company's specific situation, please be informed that our office will be closed from January 15th, 2023 to January 31th, 2023 for Spring Festival holiday, and return to normal work on February 1st, with a total of 17 days off. We apologize for the inconvenience caused by the holiday! Please schedule your order to avoid any delays. Thank you for your continuous attention and support to our company!
General Batten Light

General Batten Light

General Batten Light is commonly used in commercial and industrial settings such as offices, conference rooms, hotels, libraries, classrooms, and stores, among others.
Things you need to know about DALI D4i, DT6, DT8

Things you need to know about DALI D4i, DT6, DT8

D4i is a new DiiA specification that defines the DALI protocol in the Internet of Things (IoT) age. A DALI specialist would claim that D4i is ideal for intra-luminaire DALI.
这是描述信息

Shenzhen Toppo Lighting Company Limited

Tel:86-755-84296868  86-755-84296818     
Fax:86-755-84296866
E-mail:
info@toppolighting.com      inquiry@toppolighting.com

 

COPYRIGHT © 2022 Shenzhen Toppo Lighting Company Limited. ALL RIGHTS RESERVED  SEOTag  粤ICP备10224078号-1   Powered by www.300.cn